Back to Modalities
Textual Modality for: 508509.2 - Power transmission apparatus
Code | Title | Description | Word Counts | URL |
---|---|---|---|---|
508509.2 | 1910.219 - Mechanical power-transmission apparatus. | Occupational ... | All power-transmission equipment shall be inspected at intervals not exceeding 60 days and be kept i... | Total words: 3,627 | power: 5 | transmission: 5 | apparatus: 5 | View |
508509.2 | 29 CFR 1910.219 -- Mechanical power-transmission apparatus. | All mechanical power transmission apparatus located in basements, towers, and rooms used exclusively... | Total words: 4,400 | power: 5 | transmission: 5 | apparatus: 4 | View |
508509.2 | 29 CFR 1926.307 -- Mechanical power-transmission apparatus. | (5) Power-transmission apparatus located in basements. All mechanical power transmission apparatus l... | Total words: 4,460 | power: 6 | transmission: 5 | apparatus: 4 | View |
508509.2 | Occupational Safety and Health Administration | The shaft's diameters that can be used are 3-inch, 4-inch and 4 5/16-inches. The length of the expos... | Total words: 698 | power: 2 | transmission: 2 | apparatus: 2 | View |
508509.2 | Standard Interpretations - Occupational Safety and Health Administration | 1910.219(m) - Acceptable alternative to metal guards in mechanical power-transmission apparatus. - 0... | Total words: 427 | apparatus: 1 | View |
508509.2 | Directive: STD 1-12.19, Guarding of belts and pulleysPDF | To clarify and provide enforcement guidelines for belt and pulley power transmission apparatus. Scop... | Total words: 1,681 | power: 15 | transmission: 12 | apparatus: 4 | View |
508509.2 | 1926.307 - Mechanical power-transmission apparatus. | Occupational ... | All power-transmission equipment shall be inspected at intervals not exceeding 60 days and be kept i... | Total words: 3,571 | power: 6 | transmission: 5 | apparatus: 5 | View |
508509.2 | Mechanical Power-Transmission Apparatus | NIOSH | CDC | Care of Equipment; Is all power-transmission equipment inspected every 60 days or less and kept in g... | Total words: 933 | power: 2 | transmission: 1 | apparatus: 3 | View |
508509.2 | Mechanical Power -- Transmission Apparatus; Mechanical Power Presses ... | I. Mechanical Power-Transmission Apparatus OSHA standards 29 CFR 1910.219 and 29 CFR 1926.307 contai... | Total words: 1,925 | power: 12 | transmission: 4 | apparatus: 8 | View |
508509.2 | MACHINERY AND MACHINE GUARDING - National Oceanic and Atmospheric ... | This section deals with 29 CFR Subpart O - 1910.219 which contains detailed requirements for the saf... | Total words: 102 | power: 1 | apparatus: 2 | View |
508509.2 | GAO-25-106838, LASER COMMUNICATIONS: Space Development Agency Should ... | View GAO‑25‑106838.For more information, contact Jon Ludwigson at (202) 512-4841 or ludwigsonj@g... | Total words: 13,676 | power: 3 | transmission: 18 | View |
508509.2 | Electric Power Generation, Transmission, and Distribution Industry ... | 1910.219, Mechanical power-transmission apparatus. Related Information: 1910 Subpart R - Special Ind... | Total words: 822 | power: 16 | transmission: 13 | apparatus: 1 | View |
508509.2 | Creating Jobs With Clean Energy: Governor Hochul Announces Approval of ... | The new solar facility will consist of the solar array and associated support equipment, along with ... | Total words: 904 | power: 4 | transmission: 3 | View |
508509.2 | 1926.300 - General requirements. - Occupational Safety and Health ... | All hand and power tools and similar equipment, whether furnished by the employer or the employee, s... | Total words: 1,030 | power: 9 | apparatus: 1 | View |
508509.2 | Mechanical power-transmission apparatus: compliance with current ... | This is in response to your letter of February 6, concerning 29 CFR 1910.219, mechanical power-trans... | Total words: 304 | apparatus: 3 | View |
508509.2 | eTool : Machine Guarding - Introduction - Occupational Safety and ... | The power transmission apparatus is all components of the mechanical system which transmit energy to... | Total words: 212 | power: 5 | transmission: 3 | apparatus: 1 | View |
508509.2 | Acceptable alternative to metal guards in mechanical power-transmission ... | Mr. Stephen Wilson Flowserve Corporate Director of Safety, Health and Environmental Affairs P.O. Box... | Total words: 336 | apparatus: 2 | View |
508509.2 | Machine guarding and compliance with 29 CFR 1910.219 (m ... | Question: Does a guard that is held firmly in place without the use of screws or bolts, and cannot s... | Total words: 427 | power: 1 | transmission: 1 | apparatus: 1 | View |
508509.2 | Occupational Safety and Health Administration | This memorandum is in response to a request for interpretative guidance as to whether all unguarded ... | Total words: 256 | power: 3 | transmission: 3 | apparatus: 3 | View |
508509.2 | POST-TEST ANSWER SHEET - Occupational Safety and Health AdministrationPDF | As a general rule, power transmission apparatus is best protected by which of the following? a) Pres... | Total words: 434 | power: 1 | transmission: 1 | apparatus: 1 | View |